A meter socket base is a standard electrical fitting designed to securely accommodate an electricity meter. It also provides a sturdy, weatherproof connection point for the incoming service power cables running into your property.
Most models come as a metal enclosure fitted with a hinged cover, and they are generally installed on the exterior wall of a building right beside the main power service entry point.
Specifications of 100A Meter Sockets
|
Model |
GTFP-100A/5J |
|
Reference voltage |
600 Vac |
|
Reference current |
100 Amp |
|
Wiring system |
1-phase, 2-wire/3-wire |
|
Top opening |
1″ to 2-1/2″ optional |
|
Terminal |
5 jaws/terminals |
|
Form |
1S, 2S |
|
Jaws |
Tinned copper jaw |
|
Connector |
Steel wiring terminal |
|
Insulator |
Flame-retardant retardant, high temperature, polycarbonate |
|
Enclosure |
NEMA 3R type construction electrostatically applied epoxy baked gray powder finished |
|
Dimension |
226.5 x 194 x 111 mm |
Outline Dimensions

|
Product Number |
Description |
Outline Dimensions (H x W x D) |
|
GTFP - 100A/5J |
1 Phase, 100A, 5 jaw, ring type |
226.5 x 194 x 111 |
|
GTFP - 100A/5J |
1 Phase, 100A, 5 jaw, ring type with Hub |
226.5 x 194 x 111 |
Features
Enclosure
Manufactured from 1.0-1.5mm galvanized steel sheet with a baked gray powder polyester paint finish, It delivers superior anti-corrosion performance, extending its service lifespan across diverse operating environments.
Single-Phase Suitability
Perfectly designed for single-phase wiring, with a maximum service voltage of 600Vac, meeting standard electrical system requirements.
Easy Installation
AGenerous gutter space for cable routing. Convenient knockouts on the side, back, and bottom allow for flexible conduit connections. Lay-in type terminals with pressure plates enable quick and easy wire connections. The sockets can accept hubs from1''1-2'' size, enhancing installation versatility.
Replacement Block Assemblies Compatibility
If you need maintenance or component upgrades later, our matching replacement block assemblies PB100-4J (compatible with GTFP-100A/4J) and PB100-5J (compatible with GTFP-100A/5J) simplify long-term servicing and upkeep of your meter socket setup.
Applications
Here are key application scenarios:
Single-family homes
Main power connection for regular residential electricity use.
01
Townhouses & rental units
Standard metering fitting for multi-family small dwellings.
02
Small shops & offices
Light commercial spaces with low power loads.
03
Garages and farm sheds
Auxiliary power supply for outbuildings.
04
Small workshops
Low-demand industrial or DIY working spaces.
05
Customization
We understand that every project may have unique requirements. Our 100A meter sockets offer customization possibilities as follows:
Color Customization
While the standard baked gray powder polyester paint provides excellent corrosion resistance, we can customize the paint color to match your project's aesthetic or branding needs. Whether you need a specific shade to blend with the electrical panel's surroundings in a high-end commercial space or a color that aligns with your home's exterior theme, we are able to accommodate such requests.
Terminal and Wiring Configurations
Depending on your specific electrical system setup, we can customize the terminal types and wiring configurations. If you have special requirements for wire connections, such as unique terminal sizes or arrangements for easier installation in a compact electrical panel, our team will work with you to create a tailored solution.
Conduit Hub Adaptations
If your project requires non-standard conduit hub sizes beyond the 1" to 2 - 1/2" range, or specific hub designs for specialized conduit systems, we can customize the meter socket to fit. This ensures seamless integration with your existing or planned conduit infrastructure.
Enclosure Customization
We provide comprehensive custom sizing services for meter sockets. Based on your drawings, load specifications and on-site installation conditions, our technical team develops meter bases with custom length, width and depth, alongside optimized internal wiring space to fit your exact project specifications.
Why Choose Our 100A Meter Sockets?
Quality Assurance
Manufactured with top-quality materials and stringent production standards, our meter bases guarantee steady operation and full electrical safety.
Versatility
Suitable for a range of single-phase electrical metering needs, with features that adapt to different installation scenarios.
Durability
Featuring anti-corrosion construction and heavy-duty build, our products cut down replacement frequency and maintenance work, helping you save significant time and operating costs over years of outdoor use.
Customization Flexibility
We customize items per your exact project specs to meet all your practical and visual requirements.
Our Factory
Our factory features comprehensive production equipment dedicated to distribution box manufacturing, alongside a robust team of technicians and production specialists. Ongoing equipment upgrades allow us to cater to the broad range of customized specifications requested by global buyers.

FAQ
Q: 1. When can I get the quotation?
A: We usually quote within 24 hours after we get your inquiry.
Q: 2. How can I get a sample to check your quality?
A: After price confirmation, you can require for samples to check our quality. If you need the samples, we would like to send sample.
Q: 3. What kind of files do you accept for products?
A: PDF, Core Draw, high resolution JPG.
Q: 4. Can you do the design for requirement.
A: Yes. We employ a seasoned professional team with abundant expertise covering the full cycle of electrical enclosure design, development and manufacturing.
Q: 5. Do I need a licensed electrician to install it?
A: Yes. Improper wiring poses safety risks and may not pass local electrical code checks.
Q: 6. Can meter base be mounted flush against exterior walls?
A: Pre-punched mounting holes on the rear panel allow flush surface mounting on brick, wood, concrete and vinyl exterior walls..
Q: 7. Can I upgrade from a 100A socket to a 200A socket without changing the service entrance cable?
A: No. The meter socket rating must match or exceed the service entrance cable rating and the main breaker rating. If you are upgrading your service amperage, the entire system-including the service entrance conductors (SEU/SE-R cable) and the main distribution panel-must be evaluated and likely upgraded by a licensed electrician to handle the increased load safely.
Hot Tags: gtfp-100a/5 jaw 100 amp 5 terminal meter socket base, China gtfp-100a/5 jaw 100 amp 5 terminal meter socket base manufacturers, suppliers, factory, 5 Jaw Aluminum Enclosure Meter socket, Round Aluminum Enclosure Meter socket, 100a meter socket, 100a meter socket base, 100 amp meter sockets, 4 terminal Meter socket base