A sixteen-circuit load center rated at 125 A for single-phase 120/240 VAC distribution. It is designed for properties with dense branch-circuit requirements, including multi-unit dwellings, commercial complexes, and light industrial facilities where a single panel must consolidate a large number of circuits under a unified main service.
Specifications
|
Model |
QOL-16 |
|
Reference voltage |
120/240VAC |
|
Reference current |
100A |
|
Number of circuits |
16*1″ |
|
Wiring system |
1-phase |
|
Knockout |
Provide on all sides of enclosure |
|
Connector |
ALUMINUM/COPPER |
|
Insulator |
High temperature, polycarbonate |
|
Front type |
Surface/Flush |
|
Enclosure |
0.8-2.0 mm steel/galvanized steel |
|
Model |
Mount |
Main Amps |
Circuits |
Best For |
|
QOL1F/S |
Flush/Surface |
100A |
1 |
Main disconnect or single large load (e.g., well pump) |
|
QOL2FNT/SNT |
Flush/Surface |
100A |
2 |
Small sub-panel or dual-circuit setup |
|
QOL2F/S |
Flush/Surface |
100A |
2 |
General purpose 2-circuit panel |
|
QOL4F/S |
Flush/Surface |
100A |
4 |
Garage, shed, or small apartment |
|
QOL6F/S |
Flush/Surface |
125A |
6 |
Medium home addition or workshop |
|
QOL8F/S |
Flush/Surface |
125A |
8 |
Whole-house upgrade (small home) |
|
QOL12F/S |
Flush/Surface |
125A |
12 |
Larger home or commercial tenant space |
|
QOL16F/S |
Flush/Surface |
125A |
16 |
Multi-unit dwelling or light industrial |
|
QOL20F/S |
Flush/Surface |
125A |
20 |
Full residential service or mixed-use building |
Features
Plug-In Breaker Design
Sixteen QO/QOB-format breaker positions provide the density required for multi-tenant or multi-zone distribution. The layout accommodates a mix of single-pole lighting and receptacle circuits alongside double-pole appliance feeds, all within the 125 A main rating.
Heavy-Duty Steel Construction
The 0.8–2.0 mm cold-rolled or galvanized steel chassis is elongated to house sixteen breaker positions in a single row. Reinforced side rails and cross-bracing are integrated into the stamp pattern to prevent lateral flex when the panel is fully populated with breakers and conductors.
Matte Powder-Coated Finish
A thick baked polyester layer is applied uniformly across the expanded surface area. The coating seals the steel substrate against the airborne dust and particulate matter common in industrial corridors, mechanical rooms, and service tunnels.
Spacious Interior
The wiring cavity is divided into zones that align with breaker positions, allowing sixteen conductor sets to be dressed without interweaving. This zoned approach simplifies circuit identification and reduces the risk of accidental contact between energized conductors during maintenance.
Dual Mounting Options
Flush mounting is selected for finished electrical rooms where the panel must sit flush with painted walls. Surface mounting is standard in unfinished utility spaces and concrete block construction, where the full rear depth is used for conduit entry and the side clearances are needed for cover removal.
Multi-Directional Cable Entry
Knockouts are distributed across the crown, base, and sidewalls in patterns that accommodate multiple conduit sizes. With sixteen active circuits, the entry layout is designed to segregate high-amperage feeders from lower-amperage branch runs, preserving interior organization at maximum circuit density.
Grounding & Safety Compliance
Pre-installed aluminum or copper neutral and equipment grounding bus bars provide termination points for all sixteen branch circuits. The bars are extended in length to accept the full complement of ground conductors without stacking, maintaining individual grounding paths for each circuit.
Key Applications
Multi-unit apartment and condominium buildings
Commercial office floor distribution hubs
Light industrial assembly and fabrication plants
Hotel and motel electrical service rooms
School and institutional campus branch panels
Our Factory
We are equipped with complete distribution box production equipment and a strong technical and production team. Meanwhile, we have been continuously updating and upgrading our equipment to meet the diverse needs of customers.

FAQ
Q1: Is the QOL16 chassis too wide for standard 16-inch stud spacing?
A: The panel width approaches the limit of conventional stud bays. For flush mounting, verify the rough opening and stud spacing before ordering. Surface mounting avoids this constraint and is often preferred in commercial block-wall or retrofit applications.
Q2: Will sixteen branch circuits overload a 125 A main service?
A: Not necessarily. The sum of branch breaker ratings often exceeds the main rating by design-diversity factors assume not all circuits run at full load simultaneously. However, you must perform a load calculation per NEC Article 220 to verify that the calculated demand stays within 125 A.
Q3: When wiring all sixteen positions, how do I keep neutral conductors organized?
A: The neutral bus is segmented by breaker zone. Route each branch neutral directly to its corresponding bus segment without looping across adjacent circuits. This keeps conductor bundles separated and simplifies troubleshooting when a circuit needs isolation.
Q4: Should I choose copper bus bars for a panel feeding multiple apartment units?
A: Copper is recommended when the panel serves multiple tenants because it offers lower resistance under sustained load and requires less frequent maintenance. Aluminum is acceptable for cost-sensitive projects if terminations are properly prepared and inspected on a scheduled basis.
Hot Tags: qol 16 way 125amp low voltage laod center, China qol 16 way 125amp low voltage laod center manufacturers, suppliers, factory, GPD2 2 Way 50 Amp Low Voltage Electrical Load Center, QOL 20 Way 125Amp Low Voltage Laod Center, GTLS2 2 Way 60 Amp Low Voltage Electrical Load Center, GTL 812 8 Way 125 Amp Low Voltage Electrical Load Center, GTLS6 6 Way 60 Amp Low Voltage Electrical Load Center With Door, QOL 16 Way 125Amp Low Voltage Laod Center