The UTMCU8 houses eight ways on a 208 mm cold-rolled steel chassis with RAL9003 powder coat and IP20/IK05 ratings. It combines a raised 35 mm DIN rail, all-face knockouts, and a magnetic hinged lid for standard 3-bedroom house distribution.
Specifications
|
Feature |
Detail |
|
Standard Compliance |
BS EN 61439-3 (Consumer Unit), BS EN 60947-3 (Main Switch), BS EN 60898-1 (MCB) |
|
Operating Voltage |
230V AC, 50/60Hz |
|
Rated Current |
40A, 63A, 100A (depends on incoming device) |
|
Protection Rating |
IP20 (Indoor Use Only) |
|
Impact Protection |
IK05 |
|
Material |
Cold-rolled steel sheet with white RAL9003 powder coat |
|
Mounting |
Wall-mounted (Flush or Surface compatible with optional kits) |
|
Cable Entry |
Top, Bottom, Sides, Rear – Multiple knockouts (20mm, 25mm, 32mm, 40mm) |
|
Internal Layout |
Raised DIN rail, extra space for RCBOs, flexible circuit configuration |
Full Model Range – Choose Your Circuit Count
|
Model No. |
Usable Ways |
Width (mm) |
Height (mm) |
Depth (mm) |
Best For |
|
UTMCU4 |
4 ways |
123 |
243 |
108 |
Small flats, sheds, garages |
|
UTMCU5 |
5 ways |
141 |
243 |
108 |
Studio apartments, small offices |
|
UTMCU6 |
6 ways |
158 |
243 |
108 |
1–2 bedroom homes |
|
UTMCU8 |
8 ways |
208 |
243 |
108 |
Standard 3-bedroom house |
|
UTMCU10 |
10 ways |
243 |
243 |
108 |
Larger homes, light commercial |
|
UTMCU14 |
14 ways |
315 |
243 |
108 |
Multi-unit dwellings, workshops |
|
UTMCU18 |
18 ways |
394 |
243 |
108 |
Commercial tenants, large properties |
|
UTMCU22 |
22 ways |
467 |
243 |
108 |
Industrial sub-panels, complex setups |
Key Features – Built for Electricians, Trusted by Installers
CE Certified to EU/UK Standards
This 8-way chassis has cleared independent type-testing to BS EN 61439-3, BS EN 60947-3, and BS EN 60898-1. The build satisfies the criteria laid down in BS 7671.
01
Heavy-Duty Steel Enclosure
Pressed from cold-rolled carbon steel and sealed with a smooth RAL9003 polyester skin. The IK05 rating guards against the knocks of everyday family life and routine maintenance.
02
Flexible Cable Entry
Factory-punched knockouts ring the roof, floor, left wall, right wall, and back panel:
• Roof & Floor: 20 mm, 25 mm, 32 mm
• Sidewalls: 32 mm plus 40 mm slots
• Back panel: Wide trunking and conduit apertures
Cables can be drawn from any direction to suit the house layout.
03
Spacious Interior Design
The 35 mm DIN rail sits on raised pillars, opening a deep pocket beneath for smooth conductor bends. RCBOs slot in without pinching their neighbours.
04
Secure Magnetic Lid Closure
A strong magnet clamps the hinged steel lid shut against vibration and casual bumps. A light tug releases it for quick breaker reset.
05
Modular Wiring Configurations
Wire the 8-way chassis four ways:
• Main Switch for plain isolation
•Dual RCD for affordable zone splitting
• High Integrity for selective RCBO coverage
• RCD-only when acting as a sub-panel.
06
Pre-Installed Ground & Neutral Bars
Earth and neutral busbars are already inside, fitted with plenty of clamp screws. Connect the incoming PE and N conductors directly-no extra parts needed.
07
Clear Circuit Labeling Area
A removable label card is stuck to the inner lid face, ready for circuit-by-circuit notes. Future fault-finding becomes a matter of seconds.
08
Key Applications
Standard 3-bedroom semis and terraces covering upstairs/downstairs lighting, ring finals, cooker, and shower circuits
Terraced house renovations replacing ageing fuse boxes with modern MCB/RCD protection
Small bed-and-breakfast properties separating guest-room, kitchen, and owner-occupier supplies
Dental clinic waiting rooms and treatment suites isolating patient-chair, X-ray, and steriliser circuits
Community libraries dividing public-floor lighting, IT terminals, and staff-kitchen supplies
Our Factory
We are equipped with complete distribution box production equipment and a strong technical and production team. Meanwhile, we have been continuously updating and upgrading our equipment to meet the diverse needs of customers.

Fast FAQ – Answers for Pros & DIYers
Q1: Is the door finish resistant to cleaning chemicals?
A: The RAL9003 polyester powder coat withstands mild detergents and diluted disinfectants. Avoid bleach, acetone, or abrasive scouring pads that could dull the gloss.
Q2: Is the DIN rail removable for easier device fitting?
A: The DIN rail is fixed to raised stand-offs inside the chassis. While it is not designed to be removed routinely, it can be unscrewed if necessary to pre-populate devices on a bench before final installation.
Q3: Will a standard RCBO fit without the door bulging?
A: Yes. The 108 mm depth and raised DIN rail provide adequate clearance for standard single-module and double-module RCBOs commonly sold in the UK market. The door closes flush when correctly installed.
Q4: Can I replace a breaker without isolating the entire board?
A: No. Safe working practice requires the main switch to be turned off before removing or inserting any device. Live busbars are exposed when a breaker is withdrawn, so full isolation is essential.
Hot Tags: metal 8 way 8 module consumer unit, China metal 8 way 8 module consumer unit manufacturers, suppliers, factory, 22 Module Consumer Unit, metal consumer units, distribution boxes, 10 Moodule Consumer Unit, 6 Module Consumer Unit, 18 Moodule Consumer Unit